attached, but do not overtighten. Overtightening
can damage screws, greatly reducing their holding
power.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
Always attach concrete expansion anchors directly
to load-bearing concrete.
Never attach concrete expansion anchors to
concrete covered with tile, carpeting, hardwood
thicker than 5/8", custom fasteners must be
supplied by installer (not UL evaluated).
WARNING
6 of 6
ISSUED: 01-29-13 SHEET #:125-9353-1 02-23-13
8
WARNING
• Do not drill into mortar joints! Be sure to mount in a solid part of the cement or tile ooring. Material must meet
ASTM C-90 specications. It is suggested that a standard electric drill on slow setting is used to drill the hole
instead of a hammer drill.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
concrete
surface
432
Position mount assembly in desired
location. Use base plate (D) as a
template to mark holes. Drill one hole
using 5/16’’ (8 mm) drill bit to a minimum
depth of 2.5" (64mm). Concrete must be
at least 2000 psi density. Insert anchor
(I) in hole ush with the oor as shown
in gure 1a. Place mount assembly over
anchor and secure with one #14 wood
screw (H) as shown in gure 2a. Tighten
fastener. Place one plastic hex screw
cover (J) over #14 screw (H).
I
H
D
2.5”
H
J